PME-E-cooling-towers-for-RAI-in-Rome

Latent heat in cooling towers

Cooling towers exploit a natural principle as simple as effective: the forced evaporation of a minimum amount of water, compared to the main mass. This happens by subtracting heat from the mass itself; which is therefore cooled (latent heat of evaporation). The process is very simple and has been used Read more…

Cooling advisors

Cooling Advisors Cooling advisors make an accurate diagnosis of the real needs of both refrigeration and the specific context where the application is developed. Considering as main axes: Thermal program Application Environment The initial data from which we will start is the thermal program to be achieved together with the Read more…

Cooling towers corrosion

Cooling in chemical industry faces challenges such a sprocess water  acidity, which causes materials degradation. Corrosion is a constant to combat. It causes thinning cooling towers metal parts and forms deposits in pipes, resulting in inefficient operation of the equipment, which leads to shutdowns for corrective maintenance. THE CHALLENGE Steel Read more…

Purging and supply in cooling towers

Evaporative cooling towers achieve their purpose of cooling water by forcing a specific amount of water through evaporation. The quantity of water evaporated is directly proportional to the amount of heat to be dissipated. Approximately 1 litre of water is lost for every 600 Kcal of thermal load discarded. This Read more…

Cooling towers: noise in fans

Silent or standard cooling towers? A determining factor in the selection of the most suitable cooling solution is the area of installation. In the case of a civil construction (hospitals, shopping centers, air conditioning systems) a solution with low acoustic impact should be chosen to avoid noise caused by the Read more…

cooling tower 7

Evaporative cooling towers types

There are different types of cooling tower construction. During the design phase, the choice is made according to the application for which the cooling equipment is intended or the system size. The most frequent variables that can guide the selection are in general as follows: thermal power to be dissipated Read more…

We use our own and third-party cookies to analyze our services and show you advertising related to your preferences, based on a profile prepared from your browsing habits (for example, pages visited). If you continue browsing, we will consider that you accept their use. You can configure or reject the use of Cookies or obtain more INFORMATION

Los ajustes de cookies de esta web están configurados para «permitir cookies» y así ofrecerte la mejor experiencia de navegación posible. Si sigues utilizando esta web sin cambiar tus ajustes de cookies o haces clic en «Aceptar» estarás dando tu consentimiento a esto.

Cerrar